OBD
Through the diagnostic socket
The ECU stays in the car. The tool talks to the bootloader over CAN or K-line. Fastest route and no opening, but on many newer ECUs it writes only the calibration and cannot read the full flash or EEPROM.
Risk Low, if the battery is on a stable charger.
Bench
ECU out, on the desk
The ECU is removed and powered on the bench; the tool connects to its connector pins. Reads the full flash and EEPROM on most Tricore ECUs without opening the case.
Risk Low to medium. Correct wiring diagram is essential.
Boot
Case opened, boot pin
The case is opened and the processor is forced into boot mode through a test point. Used when bench is not supported or the ECU is locked (TPROT, new SW).
Risk Medium. Needs a steady hand and the right pinout.
JTAG / BDM
Debug port on the board
Direct access to the processor through its debug interface. Classic for older Motorola/Freescale ECUs (EDC16, MED9, Delphi) and for recovery after a failed write.
Risk Medium to high. Soldering or probe frame needed.
EEPROM
Memory chip on the board
The external EEPROM (95xxx, 93Cxx) is read in circuit or desoldered. Holds immobiliser data, VIN and adaptations. Needed for ECU clones and immo work.
Risk Medium. Always keep the original dump.